Advanced RS485 Remote I/O Sensor for Data Acquisition and Signal Relay

Product Details
Customization: Available
Theory: Thermal Relay
Usage: Household Appliances Relay
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (21)
  • Advanced RS485 Remote I/O Sensor for Data Acquisition and Signal Relay
  • Advanced RS485 Remote I/O Sensor for Data Acquisition and Signal Relay
  • Advanced RS485 Remote I/O Sensor for Data Acquisition and Signal Relay
  • Advanced RS485 Remote I/O Sensor for Data Acquisition and Signal Relay
  • Advanced RS485 Remote I/O Sensor for Data Acquisition and Signal Relay
  • Advanced RS485 Remote I/O Sensor for Data Acquisition and Signal Relay
Find Similar Products
  • Overview
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
WJ71
Phase
2
Electricity Type
Vacuum
Number of Pole
1
Load
High Power Relay
Protective Characteristics
Open Relay
Action Principle
Rectifier Type
Size
Miniature
Type
Electric Parameter Relay
Product Features
Low Cost, Small Size, Modular Design
Product Features1
The Output Relay Status Can Be Set Through The RS-
Product Features2
Three Isolation Between Signal Input, Output, and
Product Features3
Three Way Switch Input, Ten Way Relay Output
Product Features4
High Reliability, Easy Programming, and Easy Appli
Product Features5
Supports Modbus RTU Communication Protocol and Aut
Typical Applications
RS-485 Remote I/O, Data Acquisition
Typical Applications1
Acquisition and Recording of Industrial Field Data
Typical Applications2
Measurement of Sensor Signals
Transport Package
Wayjunr
Specification
120 x 70 x 43mm
Trademark
wayjunr
Origin
Guangdong, China
Production Capacity
9999

Product Description

Three DI and ten DO relay outputs, RS-485/232 remote I/OmoduleWJ71
Product Overview:
The WJ71 product realizes signal acquisition and control between sensors and hosts, used to detect switchsignalsorcontrol device operation. The WJ71 series products can be applied in industrial automation control systems withRS-232/485 bus, measurement and control of switch signals, measurement and output of high and lowlevel signals, aswell as industrial field signal isolation and long-distance transmission, etc. The product includes power conditioning, switch quantity acquisition, relay output, and RS-485 serial
communication. Each serial port can connect up to 255 WJ71 series modules, and the communication methodadoptsASCII code communication protocol or MODBUS RTU communication protocol. The baud rate can be set bycodeandcan be hung on the same RS-485 bus as control modules from other manufacturers, making it easy for computer
programming.
Advanced RS485 Remote I/O Sensor for Data Acquisition and Signal Relay
Advanced RS485 Remote I/O Sensor for Data Acquisition and Signal Relay
Product selection:


WJ71 - 
Communication interface
485: Output as RS-485 interface
232: Output as RS-232 interface
Selection Example 1: Model: WJ71-232 indicates that the communication interface is RS-232
Selection Example 2: Model: WJ71-485 indicates that the communication interface is RS-485










Company Profile
Advanced RS485 Remote I/O Sensor for Data Acquisition and Signal Relay
Shenzhen Weijunrui Technology Co., Ltd
Since: 2011
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc
Advanced RS485 Remote I/O Sensor for Data Acquisition and Signal Relay
Advanced RS485 Remote I/O Sensor for Data Acquisition and Signal Relay
WJ71 General Parameters:
Function Introduction:

(Typical @+25 ℃, Vs is 24VDC)
Input type: switch input, 3-channel (DI0~DI2). Low level: Input<1V
High level: Input 4~30V
Input resistance: 3K Ω
Output type: A-type relay output, 10 channels (DO0~DO9). Normally open output. Contact load capacity: 5A 250VAC/30VDC. Contact form: 1H
Maximum switching voltage: 250VAC/30VDC
Maximum switching current: 5A
Maximum switching power: 1250VA/150W
Communication: RS-485 or RS-232 standard character protocol and MODBUS RTU communication protocol
Baud rates (2400, 4800, 9600, 19200, 38400, 57600, 115200bps) can be selected by software
The address (0-255) can be selected by software
Communication response time: 100 ms maximum
Working power supply:+8~32VDC wide power supply range, with internal anti reverse and overvoltage protectioncircuits
Power consumption: less than 3W
Working temperature: -45~+80 ℃
Working humidity: 10~90% (no condensation)
Storage temperature: -45~+80 ℃
Storage humidity: 10~95% (no condensation)
Isolation and voltage resistance: 3 isolates between input and output power supplies, with an isolationvoltageof1500VAC
Dimensions: 120mm x 70mm x 43mm

The WJ71 remote I/O module can be used to measure four switch signals and has four relay signal outputs. 1, Switching signal input and output
Three channel switch signal input, capable of connecting dry contacts and wet contacts. Please refer to thewiringdiagram for details; Ten relay normally open contact output. 2, Communication Protocol
Communication interface: 1 standard RS-485 communication interface or 1 standard RS-232 communicationinterface, please specify when ordering and selecting. Communication Protocol: Supports two protocols, the character protocol defined by the command set andtheMODBUS RTU communication protocol. The module automatically recognizes communicationprotocols and can achieve network communication with various brands of PLCs, RTUs, or computermonitoring systems. Data format: 10 digits. 1 start bit, 8 data bits, and 1 stop bit. The communication address (0-255) and baud rate (2400, 4800, 9600, 19200, 38400, 57600, 115200bps) canbeset;The communication network can reach a maximum distance of 1200 meters and is connectedthroughtwisted pair shielded cables. High anti-interference design of communication interface, ± 15KV ESD protection, communication responsetimeless than 100mS. 3, anti-interference
Checksums can be set as needed. There is a transient suppression diode inside the module, which caneffectivelysuppress various surge pulses and protect the module.
FAQ
Q: How to contact you?
A: Please contact us via email or online customer service

Send your message to this supplier