8-CH Di Switch Signal to RS485/232 Converters Data Acquisition Modbus RTU
|
Still deciding? Get samples of $ !
Order Sample
|
Product Details
| Customization: | Available |
|---|---|
| Conductive Type: | Bipolar Integrated Circuit |
| Input Type: | RS485/RS232 |
Shipping
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Payment Guarantee
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Secured Trading Service
Gold Member Since 2025
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Self-branded
High Repeat Buyers Choice
In-stock Capacity
Fast Delivery
The supplier has 4 Self-brands, check the Audit Report for more information
More than 50% of buyers repeatedly choose the supplier
The supplier has In-stock capacity
The supplier can deliver the goods within 15 days
Sign In to see all verified strength labels (21)
Find Similar Products
Basic Info.
- Model NO.
- WJ62
- Integration
- GSI
- Operating Temperature
- -40℃ - 85℃
- Resolution
- 12 Bit
- Shape
- DIP
- Technics
- Semiconductor IC
- Features
- Each Input Channel Adopts Optical Isolation
- Features1
- Support Modbus RTU Communication Protocol
- Applications
- Level Signal Measurement, Monitoring and Control
- Applications1
- RS-485 Remote I / O, Data Acquisition
- Applications2
- Switching Signal Acquisition
- Applications3
- Medical, Industrial Product Development
- Quantity
- 99999
- Advantage
- Industrial Signal Isolation and Long-Term Transmi
- Transport Package
- Boxed
- Specification
- 120 mm x 70 mm x 43mm
- Trademark
- wayjunr
- Origin
- Guangdong, China
- Production Capacity
- 99999
Packaging & Delivery
- Package Size
- 20.00cm * 20.00cm * 20.00cm
- Package Gross Weight
- 0.200kg
Product Description
8-ch DI Switch Signal to RS485/232 Converters (WJ62 Series)
Features:
>> Eight channels switch signal acquisition,isolated RS-485/232 output
>> Each input channel adopts optical isolation
>> Can read level status of each channel via the RS-485/232 interface
>> Input/output: 3000VDC isolation
>> Wide power supply range: 8 ~ 32VDC
>> High reliability, easy programming, easy application
>> DIN35 Rail-mounted
>> Can programme setting module address,baud rate
>> Support Modbus RTU communication protocol
>> Dimensions: 120 mm x 70 mm x 43mm
Applications:
>> level signal measurement, monitoring and control
>> RS-485 remote I / O, data acquisition
>> Intelligent building control, security engineering applications
>> RS-232/485 bus in industrial automation control system
>> Industrial signal isolation and long-term transmission
>> Equipment operation monitoring
>> Sensor signal measurement
>> Industrial data acquisition and recording
>> Medical, industrial product development
>> Switching signal acquisition
>> Eight channels switch signal acquisition,isolated RS-485/232 output
>> Each input channel adopts optical isolation
>> Can read level status of each channel via the RS-485/232 interface
>> Input/output: 3000VDC isolation
>> Wide power supply range: 8 ~ 32VDC
>> High reliability, easy programming, easy application
>> DIN35 Rail-mounted
>> Can programme setting module address,baud rate
>> Support Modbus RTU communication protocol
>> Dimensions: 120 mm x 70 mm x 43mm
Applications:
>> level signal measurement, monitoring and control
>> RS-485 remote I / O, data acquisition
>> Intelligent building control, security engineering applications
>> RS-232/485 bus in industrial automation control system
>> Industrial signal isolation and long-term transmission
>> Equipment operation monitoring
>> Sensor signal measurement
>> Industrial data acquisition and recording
>> Medical, industrial product development
>> Switching signal acquisition
Product Overview:
WAYJUN WJ62 series products realize the signal acquisition between sensor and host, to measure the switching signal.
WJ62 series can be used in RS-232/485 bus industrial automation control system,switching signal measurement,
monitoring and control, high and low leveal signal measurement,industrial field signal isolation and long-term industrial
transmission and so on.
Products include power supply isolation, signal isolation, linearization, A/D conversion and RS-485 serial
communication. Each serial interface can connect up to 255 pieces WJ62 Series modules, communication using ASCII
code or MODBUS RTU communication protocol, and its instruction set compatible with the ADAM modules, baud rate
can been set by the code, with other manufacturers control module hang in the same RS-485 bus for easy programming.
WAYJUN WJ62 series products realize the signal acquisition between sensor and host, to measure the switching signal.
WJ62 series can be used in RS-232/485 bus industrial automation control system,switching signal measurement,
monitoring and control, high and low leveal signal measurement,industrial field signal isolation and long-term industrial
transmission and so on.
Products include power supply isolation, signal isolation, linearization, A/D conversion and RS-485 serial
communication. Each serial interface can connect up to 255 pieces WJ62 Series modules, communication using ASCII
code or MODBUS RTU communication protocol, and its instruction set compatible with the ADAM modules, baud rate
can been set by the code, with other manufacturers control module hang in the same RS-485 bus for easy programming.


Product Selection | WJ62 | |
Communication Interface 485: output is RS-485 interface 232: output is RS-232 interface | ||
Sample 1: part No.:WJ62-232 means output is RS-232 interface Sample 2: part No.: WJ62-485 means output is RS-485 interface | ||
Company Profile

Shenzhen Weijunrui Technology Co., Ltd
Since: 2011
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc


Global Showrooms
Factory Capabilities
WJ62 General parameters:
(typical @ +25 ℃, Vs is 24VDC)
Input type:switching input
Low level: input <1V
High level: input 4-30V
Input Resistance:3K
Communication: RS-485 protocol or RS-232 standard characters protocols and MODBUS RTU communication protocol
Baud Rate (2400,4800,9600,19200,38400 bps) can be selected via software
Address (0 to 255) can be selected via software
Communication Response Time: 100 ms maximum
Power Supply: +8 ~ 32VDC wide range power supply, internal anti-reverse and over-voltage protection circuit
Power Loss: less than 0.5W
Operating Temperature: - 45 ~ +85℃
(typical @ +25 ℃, Vs is 24VDC)
Input type:switching input
Low level: input <1V
High level: input 4-30V
Input Resistance:3K
Communication: RS-485 protocol or RS-232 standard characters protocols and MODBUS RTU communication protocol
Baud Rate (2400,4800,9600,19200,38400 bps) can be selected via software
Address (0 to 255) can be selected via software
Communication Response Time: 100 ms maximum
Power Supply: +8 ~ 32VDC wide range power supply, internal anti-reverse and over-voltage protection circuit
Power Loss: less than 0.5W
Operating Temperature: - 45 ~ +85℃
Humidity: 10 ~ 90% (no condensation)
Storage Temperature: - 45 ~ +85℃
Storage Humidity: 10 ~ 95% (no condensation)
Isolation Voltage: input / output: 3KVDC, 1 minute, leak current:1mA
Which output signal and power supply are common ground.
Shock Voltage: 3KVAC, 1.2/50us (peak)
Dimensions: 120 mm x 70 mm x 43mm
Storage Temperature: - 45 ~ +85℃
Storage Humidity: 10 ~ 95% (no condensation)
Isolation Voltage: input / output: 3KVDC, 1 minute, leak current:1mA
Which output signal and power supply are common ground.
Shock Voltage: 3KVAC, 1.2/50us (peak)
Dimensions: 120 mm x 70 mm x 43mm
Function Description:
WJ62 Switch signal isolation acquisition module can be used to measure eight channels switching signal.
1. Switch signal input
eight channels switching signal.Not only each channel isolation,but also input/output isolation.
2. Communication protocol
Communication Interface: one channel standard RS-485 communication interface, or one standard RS-232
communication interface, specify when ordering.
Communication Protocols: supports two protocols, characters protocol of the command set defined and MODBUS
RTU communication protocol. Can be programmed using the kind of communication protocol, can be
achieved with PLC, RTU of many Brands or computer monitoring system for network communication.
Data Format: 10 Bits. 1 start bit,8 data bits,1 stop bit.
Address: (0 to 255) and baud rate (2400,4800,9600,19200,38400 bps) can be set, the most long-distance about
communication networks is up to 1200 meters, through the twisted-pair shielded cable.
Communication interface of high anti-jamming design, ± 15KV ESD protection, communication response time is less
than 100mS.
3. Anti-jamming
According to need to set the checksum. Module internal has transient suppression diodes, can inhibit a variety of
surge pulse, protection module, and internal digital filter can also be well suppressed from the grid frequency
interference.
WJ62 Switch signal isolation acquisition module can be used to measure eight channels switching signal.
1. Switch signal input
eight channels switching signal.Not only each channel isolation,but also input/output isolation.
2. Communication protocol
Communication Interface: one channel standard RS-485 communication interface, or one standard RS-232
communication interface, specify when ordering.
Communication Protocols: supports two protocols, characters protocol of the command set defined and MODBUS
RTU communication protocol. Can be programmed using the kind of communication protocol, can be
achieved with PLC, RTU of many Brands or computer monitoring system for network communication.
Data Format: 10 Bits. 1 start bit,8 data bits,1 stop bit.
Address: (0 to 255) and baud rate (2400,4800,9600,19200,38400 bps) can be set, the most long-distance about
communication networks is up to 1200 meters, through the twisted-pair shielded cable.
Communication interface of high anti-jamming design, ± 15KV ESD protection, communication response time is less
than 100mS.
3. Anti-jamming
According to need to set the checksum. Module internal has transient suppression diodes, can inhibit a variety of
surge pulse, protection module, and internal digital filter can also be well suppressed from the grid frequency
interference.
Certifications
FAQ
Q: How to contact you?
A: Please contact us via email or online customer service
A: Please contact us via email or online customer service
Send your message to this supplier
People who viewed this also viewed
Product Groups
Find Similar Products By Category
- Supplier Homepage
- Products
- Remote IO module
- 8-CH Di Switch Signal to RS485/232 Converters Data Acquisition Modbus RTU
Related Categories
Hot Searches
More