Grating Ruler and Magnetic Grating Ruler Converted to Standard Modbus RTU Protocol

Still deciding? Get samples of $ !
Order Sample
Product Details
Customization: Available
Typical Applications: Measurement of Grating Ruler Pulse Signal
Typical Applications1: Measurement of Magnetic Grating Ruler Pulse Signal
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (21)
  • Grating Ruler and Magnetic Grating Ruler Converted to Standard Modbus RTU Protocol
  • Grating Ruler and Magnetic Grating Ruler Converted to Standard Modbus RTU Protocol
  • Grating Ruler and Magnetic Grating Ruler Converted to Standard Modbus RTU Protocol
  • Grating Ruler and Magnetic Grating Ruler Converted to Standard Modbus RTU Protocol
  • Grating Ruler and Magnetic Grating Ruler Converted to Standard Modbus RTU Protocol
  • Grating Ruler and Magnetic Grating Ruler Converted to Standard Modbus RTU Protocol
Find Similar Products
  • Overview
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
WJ153
Typical Applications2
Three Coordinate System Position Measurement
Typical Applications3
Ball Grid Ruler Pulse Signal Measurement
Typical Applications4
The Grating Ruler Signal Is Transmitted Remotely T
Typical Applications5
Encoder Pulse Signal Measurement
Wide Power Supply Range
8~32VDC
Product Features
Users Can Program Module Addresses, Baud Rates, Et
Product Features1
Can Be Used for Measuring Range Angle or Speed
Product Features2
Measurement Values Support Automatic Saving in CAS
Product Features3
Pulse Input Supports PNP and NPN Inputs
Transport Package
Wayjunr
Specification
79x69.5x25mm
Trademark
wayjunr
Origin
Guangdong, China
Production Capacity
9999

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 20.00cm
Package Gross Weight
0.200kg

Product Description

1-channel grating ruler magnetic grating ruler encoder 4-fold pulse counter, ModbusRTU module WJ153
Product Overview:
The WJ153 product realizes signal acquisition between sensors and hosts, used to decode grating ruler magneticgrating ruler signals. The WJ153 series products can be applied in RS-485 bus industrial automation control systems, automated machine tools, industrial robots, three coordinate positioning systems, displacement measurement, strokemeasurement, angle measurement, speed measurement, product meters, and more. The product includes signal acquisition, pulse signal capture, signal conversion, and RS-485 serial communication.Each serial port can connect up to 255 WJ153 series modules, and the communication method adopts ASCII codecommunication protocol or MODBUS RTU communication protocol. The baud rate can be set by code and canbehungon the same RS-485 bus as control modules from other manufacturers, making it easy for computer programming The WJ153 series products are intelligent monitoring and control systems based on microcontrollers. All user set
configuration information such as address, baud rate, data format, checksum status, etc. are stored in non-volatilememory EEPROM. The WJ153 series products are designed and manufactured according to industrial standards, with no isolationbetween signal inputs/outputs, strong anti-interference ability, and high reliability. The working temperature rangeis-45 ℃ to+85 ℃.
Grating Ruler and Magnetic Grating Ruler Converted to Standard Modbus RTU Protocol
Grating Ruler and Magnetic Grating Ruler Converted to Standard Modbus RTU Protocol















Company Profile
Grating Ruler and Magnetic Grating Ruler Converted to Standard Modbus RTU Protocol
Shenzhen Weijunrui Technology Co., Ltd
Since: 2011
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc
Grating Ruler and Magnetic Grating Ruler Converted to Standard Modbus RTU Protocol
Grating Ruler and Magnetic Grating Ruler Converted to Standard Modbus RTU Protocol
Function Introduction:
General parameters of WJ153:

The WJ153 remote I/O module can be used to measure the signal of one grating ruler magnetic grating ruler encoder. 1, Signal input
1-channel grating ruler magnetic grating ruler encoder signal input, can be connected to NPNand PNPsignals, andthe input type can be set through commands. 2, Communication Protocol
Communication interface: 1 standard RS-485 communication interface. Communication Protocol: Supports two protocols, the character protocol defined by the command set andtheMODBUS RTU communication protocol. The module automatically recognizes communicationprotocols and can achieve network communication with various brands of PLCs, RTUs, or computermonitoring systems. Data format: 10 digits. 1 start bit, 8 data bits, and 1 stop bit. No verification. The communication address (0-255) and baud rate (2400, 4800, 9600, 19200, 38400, 57600, 115200bps) canbeset;The communication network can reach a maximum distance of 1200 meters and is connectedthroughtwisted pair shielded cables. High anti-interference design of communication interface, ± 15KV ESD protection, communication responsetimeless than 100mS. 3, anti-interference
Checksums can be set as needed. There is a transient suppression diode inside the module, which caneffectivelysuppress various surge pulses, protect the module, and the internal digital filter can also effectively suppresspowerfrequency interference from the power grid.
Input type: Encoder AB signal input, 1 channel (A0/B0). Low level: Input<1V
High level: Input 3.5~30V
The frequency range is 0-50KHz. Encoder counting range -2147483647 ~+2147483647
Input resistance: 30K Ω
Communication: RS-485 standard character protocol and MODBUS RTU communication protocol
Baud rates (2400, 4800, 9600, 19200, 38400, 57600, 115200bps) can be selected by software
The address (0-255) can be selected by software
Communication response time: 100 ms maximum
Working power supply:+8~32VDC wide power supply range, with internal anti reverse and overvoltage protectioncircuits
Power consumption: less than 1W
Working temperature: -45~+80 ℃
Working humidity: 10~90% (no condensation)
Storage temperature: -45~+80 ℃
Storage humidity: 10~95% (no condensation)
Dimensions: 106 mm x 59mm x 24mm
FAQ