Product Details
Customization: Available
Conductive Type: Bipolar Integrated Circuit
Input Type: Differential
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
T/T PayPal ApplePay GooglePay visa mastercard american express discover
JCB diners club PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (21)
  • Resistance Potentiometer Electronic Ruler to Network Modbus TCP Data Collection Mqtt Wj185
  • Resistance Potentiometer Electronic Ruler to Network Modbus TCP Data Collection Mqtt Wj185
  • Resistance Potentiometer Electronic Ruler to Network Modbus TCP Data Collection Mqtt Wj185
  • Resistance Potentiometer Electronic Ruler to Network Modbus TCP Data Collection Mqtt Wj185
  • Resistance Potentiometer Electronic Ruler to Network Modbus TCP Data Collection Mqtt Wj185
  • Resistance Potentiometer Electronic Ruler to Network Modbus TCP Data Collection Mqtt Wj185
Find Similar Products
  • Overview
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
WJ183
Integration
GSI
Operating Temperature
-40℃ - 85℃
Resolution
12 Bit
Shape
DIP
Technics
Semiconductor IC
Product Features
Signal Acquisition and Conversion of Resistance Po
Product Features1
Supports Communication Protocols Such as TCP Serve
Product Features2
Built in Web Page Function, Data Can Be Queried Th
Product Features4
High Reliability, Easy Programming, and Easy Appl
Product Features3
Standard DIN35 Rail Installation, Convenient for C
Product Features5
Low Cost, Small Size, Modular Design
Product Features6
Signal Measurement, Monitoring, and Mqtt Reporting
Transport Package
Wayjunr
Specification
106 mm x 59mm x 37mm
Trademark
WAYJUNR
Origin
Guangdong, China
Production Capacity
9999

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 20.00cm
Package Gross Weight
0.200kg

Product Description

 Resistance potentiometer electronic ruler conversion network Modbus TCPand
 MQTTnetworkdata WJ183
Product features:
 Signal acquisition and conversion of resistance potentiometer electronic ruler to standard Modbus TCP protocol
 Supports communication protocols such as TCP Server, UDP, MQTT, etc
 Built in web page function, data can be queried through web pages
 Wide power supply range: 8~32VDC
 High reliability, easy programming, and easy application
 Standard DIN35 rail installation, convenient for centralized wiring
 Users can set module IP addresses and other parameters on the webpage
 Low cost, small size, modular design
 Dimensions: 106 mm x 59mm x 37mm
 Typical applications:
 Signal measurement, monitoring, and MQTT reporting
 TCPnetwork, data collection
 Intelligent building control, security engineering and other application systems
 Industrial automation control system based on TCP network
 Industrial site signal isolation and long-distance transmission
 Equipment operation monitoring, MES system
 Potentiometer, displacement signal measurement
 Acquisition and recording of industrial field data
 Development of medical and industrial control products
 Signal acquisition of resistance potentiometer electronic ruler
Resistance Potentiometer Electronic Ruler to Network Modbus TCP Data Collection Mqtt Wj185
Resistance Potentiometer Electronic Ruler to Network Modbus TCP Data Collection Mqtt Wj185
Product model
WJ183- R-RJ4

Input type:  R
code     explain
3Ru     Threewireresistor: universal in the range
            of 100 Ω~500K Ω
2R1     Two wire resistor: 0-50 Ω
2R2     Two wire resistor: 0-100 Ω
2R3     Two wire resistor: 0-200 Ω
2R4     Two wire resistor: 0-500 Ω
2R5     Two wire resistor: 0-1K Ω
2R6     Two wire resistor: 0-2K Ω
2R7     Two wire resistor: 0-5K Ω
2R8     Two wire resistor: 0-10K Ω   
2Ru     Two wire resistor: user-defined
Communication interface: RJ45
code    explain
RJ45    Output as RJ-45 network interface

Selection Example 1:
 Model: WJ183-3Ru-RJ45 represents the potentiometer signal input within the range of 100 Ω~500K Ω for a three wire
 resistor resistance, and the output is an RJ-45 network interface
Selection Example 2:
 Model: WJ183-2R8-RJ45 represents a two-wire resistor with a resistance input in the range of 0-10K Ω and an RJ-45
 network interface output







Company Profile
Resistance Potentiometer Electronic Ruler to Network Modbus TCP Data Collection Mqtt Wj185
Shenzhen Weijunrui Technology Co., Ltd
Since: 2011
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc
Resistance Potentiometer Electronic Ruler to Network Modbus TCP Data Collection Mqtt Wj185
Resistance Potentiometer Electronic Ruler to Network Modbus TCP Data Collection Mqtt Wj185
 WJ183 General Parameters:
Function Introduction:

 (Typical @+25 ℃, Vs is 24VDC)
 Input type: Three wire potentiometer resistor input
 Accuracy: 0.1%
 Temperature drift: ± 50 ppm/℃ (± 100 ppm/℃, maximum)
 Input resistance: greater than 1M Ω
 Bandwidth:-3 dB 10 Hz
 Conversion rate: 16FPS (factory default value, users can modify the conversion rate on the webpage.)
 You can set the AD conversion rate to 2SPS, 4SPS, 8SPS, 16SPS, 32SPS, 50SPS, 80SPS, 100SPS by sending
 commands
 Common moderejection (CMR): 120 dB (1k Ω Source Imbalance @ 50/60 Hz)
 Normal mode suppression (NMR): 60 dB (1k Ω Source Imbalance @ 50/60 Hz)
 Input protection: overvoltage protection, overcurrent protection
 Communication: MODBUS TCP communication protocol or TCP socket character protocol or MQTT protocol
 Webpage: Supports web access module and web page setting module parameters.
 Interface: RJ-45 network interface.
 Communication response time: 10 ms maximum
 Working power supply:+8~32VDC wide power supply range, with internal anti reverse and overvoltage protection
 circuits
 Powerconsumption:lessthan3W
 Workingtemperature:-45~+80℃
 Workinghumidity:10~90%(nocondensation)
 Storagetemperature:-45~+80℃
 Storagehumidity:10~95%(nocondensation)
 Dimensions:106mmx59mmx37mm

 The WJ183 remote I/O module can be used to measure potentiometer resistance signals.
 1. Potentiometer signal input
 12 bit acquisition accuracy, potentiometer resistance signal input. The product has been fully calibrated before
 leaving the factory. Users do not need to calibrate.
 2. Communication Protocol
 Communication interface: RJ-45 network interface. The two indicator lights at the network port position, the Link
 light (green light) stays on and the Data light (yellow light) stays on after the network cable is plugged in.
 Communication protocol: MODBUS TCP protocol is adopted to achieve industrial Ethernet data exchange. It can
 also communicate with modules through TCP sockets.
 Network cache: 2K bytes (for both sending and receiving)
 Communication response time: less than 10mS.
 3. Anti interference
 There is a transient suppression diode inside the module, which can effectively suppress various surge pulses and
 protect the module  The WJ183 series products include power conditioning, analog acquisition, and RJ-45 network interface
 communication.
 The communication method adopts MODBUS TCP protocol. TCP is a transport layer based
 protocol that is widely used and a reliable connection oriented protocol. Users can directly set module IP addresses,
 subnet masks, etc. on the webpage. Can be used for monitoring and controlling the operation of sensor devices.
 The WJ183 series products are intelligent monitoring and control systems based on microcontrollers, where user set
 module IP addresses, subnet masks, and other configuration information are stored in non-volatile memory EEPROM.
 The WJ183 series products are designed and manufactured according to industrial standards, with strong
 anti-interference ability and high reliability. The working temperature range is-45 ℃ to+80 ℃.