Encoder Counter Speed Measurement Modbus and Mqtt, WiFi Module Modbus TCP

Product Details
Customization: Available
Type: Rotary Encoder
Working Principle: Absolute
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (21)
  • Encoder Counter Speed Measurement Modbus and Mqtt, WiFi Module Modbus TCP
  • Encoder Counter Speed Measurement Modbus and Mqtt, WiFi Module Modbus TCP
  • Encoder Counter Speed Measurement Modbus and Mqtt, WiFi Module Modbus TCP
  • Encoder Counter Speed Measurement Modbus and Mqtt, WiFi Module Modbus TCP
  • Encoder Counter Speed Measurement Modbus and Mqtt, WiFi Module Modbus TCP
  • Encoder Counter Speed Measurement Modbus and Mqtt, WiFi Module Modbus TCP
Find Similar Products
  • Overview
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
WJ161
Readout Mode
Contact
Operating System
Contact Brush Type
Signal Output
Complementary Push-pull Output
Axle Sleeve Type
Large Diameter Type
Package
Wayjunr
Installation Form
Standard DIN35 Rail Installation
Brand
Wayjunr
Axonia
Servo Installation Type
Product Features
Can Be Used as an Encoder Counter or Speed Measure
Product Features1
Encoders Decode and Convert to Standard Modbus Tc
Product Features2
It Can Also Be Set as a 2-Channel Independent Di H
Product Features3
Di Input Supports PNP and NPN Inputs
Product Features4
Reset and Set Count Values Through WiFi
Typical Applications
Encoder Pulse Signal Measurement
Typical Applications1
Flow Meter Pulse Counting or Flow Measurement
Typical Applications2
Counting of Products on The Production Line
Typical Applications3
Measurement of Proximity Switch Pulse Signal
Typical Applications4
Pulse Counting of Water or Electricity Meters
Typical Applications5
Messystem Data Statistics
Transport Package
Wayjunr
Specification
120mm x 70mm x 43mm
Trademark
wayjunr
Origin
Guangdong, China
Production Capacity
9999

Product Description

1-channel encoder or 2-channel DI pulse counter, Modbus and MQTT, WiFi module
 WJ161
 Function Introduction:
 The WJ161 remote I/O module can be used to measure 1 encoder signal, or set as 2 independent counters or DI status
 measurement.
 1,Signal input
 1 encoder signal input or 2 independent counters, can be connected to dry and wet contacts, and the input type can
Bridesmaid-Ready - Wrinkle-resistant fabric for all-day wear  be set through commands.
 2,signal output
 1-channel DO signal output, NPN with internal pull-up, output high level approximately equal to the power supply
 voltage, low level approximately 0V, can directly drive the intermediate relay with low level.
 3,Communication Protocol
 Communication interface: WiFi network interface. Can connect to WiFi within the local area network.
 Communication protocol: MODBUS TCP protocol is adopted to achieve industrial Ethernet data exchange. It can
 also communicate with modules through TCP sockets.
 Network cache: 2K bytes (for both sending and receiving)
 Communication response time: less than 10mS.
 4,anti-interference
 There is a transient suppression diode inside the module, which can effectively suppress various surge pulses and
 protect the module.
Encoder Counter Speed Measurement Modbus and Mqtt, WiFi Module Modbus TCP
Encoder Counter Speed Measurement Modbus and Mqtt, WiFi Module Modbus TCP




Product model:
 WJ161– WiFi
Form of antenna
 Wexternal antenna
 Nbuilt-in antenna
 Xsuction cup antenna
 Communication interface
 WiFi: Output as WiFi network interface










Company Profile
Encoder Counter Speed Measurement Modbus and Mqtt, WiFi Module Modbus TCP
Shenzhen Weijunrui Technology Co., Ltd
Since: 2011
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc
Encoder Counter Speed Measurement Modbus and Mqtt, WiFi Module Modbus TCP
Encoder Counter Speed Measurement Modbus and Mqtt, WiFi Module Modbus TCP
 WJ161 General Parameters:
Typical applications:

 (Typical @+25 ℃, Vs is 24VDC)
 Input type: Encoder AB signal input, 1 channel (A0/B0).
 Low level: Input<1V
 High level: Input 3.5~30V
 The frequency range is 0-15KHz.
 Encoder counting range-2147483647 ~+2147483647
 DI counter range 0~ 4294967295
 Input resistance: 30K Ω
 Output type: DO output voltage signal, NPN with internal pull-up output, can directly drive intermediate relays. The
 internal pull-up resistor is 3K.
 Low level (0): 0V, maximum current of 100mA
 High level (1): Power supply voltage-1V,;.
 Communication: MODBUS TCP communication protocol or TCP socket character protocol, while supporting MQTT
 protocol
 Webpage: Supports web access module and web page setting module parameters.
 Interface: WiFi network interface.
 Working power supply:+8~32VDC wide power supply range, with internal anti reverse and overvoltage protection
 circuits
 Power consumption: less than 1W
 Working temperature:-45~+80 ℃
 Working humidity: 10~90% (no condensation)

Encoder pulse signal measurement
 Flow meter pulse counting or flow measurement
 Counting of products on the production line
 Counting the number of logistics packages
 Measurement of proximity switch pulse signal
The encoder signal is transmitted remotely to the industrial computer
 Pulse counting of water or electricity meters
Intelligent factory and industrial Internet of Things
Punch press count
Counting the quantity of injection molded products
MESsystem data statistics
FAQ
Q: How to contact you?
A: Please contact us via email or online customer service

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier