Rtd PT100 PT1000 Temperature to Modbus TCP Mqtt Network 8-Channel Signal Data Acquisition Module

Product Details
Customization: Available
Type: Temperature Signal Module
Measuring Medium: Humidity
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (21)
  • Rtd PT100 PT1000 Temperature to Modbus TCP Mqtt Network 8-Channel Signal Data Acquisition Module
  • Rtd PT100 PT1000 Temperature to Modbus TCP Mqtt Network 8-Channel Signal Data Acquisition Module
  • Rtd PT100 PT1000 Temperature to Modbus TCP Mqtt Network 8-Channel Signal Data Acquisition Module
  • Rtd PT100 PT1000 Temperature to Modbus TCP Mqtt Network 8-Channel Signal Data Acquisition Module
  • Rtd PT100 PT1000 Temperature to Modbus TCP Mqtt Network 8-Channel Signal Data Acquisition Module
  • Rtd PT100 PT1000 Temperature to Modbus TCP Mqtt Network 8-Channel Signal Data Acquisition Module
Find Similar Products
  • Overview
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
WJ285
Display Type
LCD
Site Display
Site Display
Accuracy
0.1
IP Rating
IP20
Certification
CE
Customized
Customized
Wide Power Supply Range
8~32VDC
Input Type
PT100 Input/PT1000 Input
Measurement Temperature Range
-200~600 ºC
Bandwidth
-3 dB 10 Hz
Powerconsumption
Lessthan3w
Quantity
9999
Advantage
Convert 8-Channel PT100/PT1000 Thermistor to Stand
Transport Package
Boxed
Specification
106mmx59mmx37mm
Trademark
wayjunr
Origin
Guangdong, China
Production Capacity
99999

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 20.00cm
Package Gross Weight
0.200kg

Product Description

 8-channel Pt100/Pt1000 temperature to Modbus TCPand MQTT network data
 acquisition module WJ285
 Product features:
 Convert 8-channel Pt100/Pt1000 thermistor to standard Modbus TCP protocol
 Supports communication protocols such as TCP Server, UDP, MQTT, etc
 Built in web page function, data can be queried through web pages
 Standard 3-wire measurement method with automatic long line compensation
 Using a 12 bitAD converter, the measurement accuracy is better than 0.1%
 The accuracy of the calibration module can be programmed through the network
 Wide power supply range: 8~32VDC
 High reliability, easy programming, and easy application
 Standard DIN35 rail installation, convenient for centralized wiring
 Users can set module IP addresses and other parameters on the webpage
 Low cost, small size, modular design
 Dimensions: 106 mm x 59mm x 37mm
 Typical applications:
 Signal measurement, monitoring, and MQTT reporting
 TCPnetwork, data collection
 Intelligent building control, security engineering and other application systems
 Industrial automation control system diagram of TCP network,
 Equipment operation monitoring, MES system
 Measurement of sensor signals
 Acquisition and recording of industrial field data
 Development of medical and industrial control products
 Pt100/Pt1000 temperature signal measurement
Rtd PT100 PT1000 Temperature to Modbus TCP Mqtt Network 8-Channel Signal Data Acquisition Module
Rtd PT100 PT1000 Temperature to Modbus TCP Mqtt Network 8-Channel Signal Data Acquisition Module

Product model:
 WJ285- Z   -RJ45

Input type: Z
Communication interface: RJ45

code   explain
Z1       PT100,-200~600℃
Z5       PT1000,-200~600℃
RJ45     Output as RJ-45 network interface

Selection example 1: Model: WJ285-Z1-RJ45 represents 8-channel PT100,-200~600 ℃ signal input, and output is
 RJ-45 network interface
Selection Example 2: Model: WJ285-Z5-RJ45 represents 8-channel PT1000, with-200~600 ℃ signal input and RJ-45
 network interface output




Company Profile
Rtd PT100 PT1000 Temperature to Modbus TCP Mqtt Network 8-Channel Signal Data Acquisition Module
Shenzhen Weijunrui Technology Co., Ltd
Since: 2011
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc
Rtd PT100 PT1000 Temperature to Modbus TCP Mqtt Network 8-Channel Signal Data Acquisition Module
Rtd PT100 PT1000 Temperature to Modbus TCP Mqtt Network 8-Channel Signal Data Acquisition Module
Global Showrooms
Factory Capabilities
WJ285 General Parameters:
 (Typical @+25 ℃, Vs is 24VDC)
 Input type: Pt100 input/Pt1000 input
 Measurement temperature range:-200~600 ℃
 Accuracy: 0.1%
 Temperature drift: ± 50 ppm/℃ (± 100 ppm/℃, maximum)
 Bandwidth:-3 dB 10 Hz
 Conversion rate: 16FPS (factory default value, users can modify the conversion rate on the webpage.)
 You can set the AD conversion rate to 2SPS, 4SPS, 8SPS, 16SPS, 32SPS, 50SPS, 80SPS, 100SPS by sending
 commands
 Commonmoderejection(CMR):120dB(1kΩSourceImbalance@50/60Hz)
 Normalmodesuppression(NMR):60dB(1kΩSourceImbalance@50/60Hz)
 Inputprotection:overvoltageprotection,overcurrentprotection
 Communication:MODBUSTCPcommunicationprotocolorTCPsocketcharacterprotocolorMQTTprotocol
 Webpage:Supportswebaccessmoduleandwebpagesettingmoduleparameters.
 Interface:RJ-45networkinterface.
 Communicationresponsetime:100msmaximum
 Workingpower supply:+8~32VDCwidepower supply range,with internal anti reverse andovervoltage protection
 circuits
 Powerconsumption:lessthan3W
 Workingtemperature:-45~+80℃
 Workinghumidity:10~90%(nocondensation)
 Storagetemperature:-45~+80℃
 Storagehumidity:10~95%(nocondensation)
 Dimensions:106mmx59mmx37mm
 Product Overview:
 WJ285 module appearance diagram
 The WJ285 product is an IoT and industrial Ethernet acquisition module that enables transparent data exchange
 between sensors and networks. The analog data from sensors can be forwarded to the network  The WJ285 series products include power conditioning, Pt100/Pt1000 temperature signal acquisition, and RJ-45
 network interface communication. The communication method adopts MODBUS TCP protocol. TCP is a transport
 layer based protocol that is widely used and a reliable connection oriented protocol. Users can directly set module IP  addresses, subnet masks, etc. on the webpage. Can be used for monitoring and controlling the operation of sensor
 devices.
 The WJ285 series products are intelligent monitoring and control systems based on microcontrollers, where user set
 module IP addresses, subnet masks, and other configuration information are stored in non-volatile memory EEPROM.
 The WJ285 series products are designed and manufactured according to industrial standards, with strong
 anti-interference ability and high reliability. The working temperature range is-45 ℃ to+80 ℃.
 Function Introduction:
 The WJ285 remote I/O module can be used to measure 8 Pt100/Pt1000 temperature signals.
 1. Temperature signal input
 12 bit acquisition accuracy, 8 temperature signal inputs. Measure temperature range-200~600 degrees. The
 product has been fully calibrated before leaving the factory. During use, users can also easily program and
 calibrate themselves.
 2. Communication Protocol
 Communication interface: RJ-45 network interface. The two indicator lights at the network port position, the Link
 light (green light) stays on and the Data light (yellow light) stays on after the network cable is plugged in.
 Communication protocol: MODBUS TCP protocol is adopted to achieve industrial Ethernet data exchange. It can
 also communicate with modules through TCP sockets.
 Network cache: 2K bytes (for both sending and receiving)
 Communication response time: less than 10mS.
 3. Anti interference
 There is a transient suppression diode inside the module, which can effectively suppress various surge pulses and
 protect the module
FAQ