0-75mv Convert to Modbus TCP Network WiFi Collection Module Mes System Sensor Signal

Product Details
Customization: Available
Conductive Type: Bipolar Integrated Circuit
Input Type: Differential
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (21)
  • 0-75mv Convert to Modbus TCP Network WiFi Collection Module Mes System Sensor Signal
  • 0-75mv Convert to Modbus TCP Network WiFi Collection Module Mes System Sensor Signal
  • 0-75mv Convert to Modbus TCP Network WiFi Collection Module Mes System Sensor Signal
  • 0-75mv Convert to Modbus TCP Network WiFi Collection Module Mes System Sensor Signal
  • 0-75mv Convert to Modbus TCP Network WiFi Collection Module Mes System Sensor Signal
  • 0-75mv Convert to Modbus TCP Network WiFi Collection Module Mes System Sensor Signal
Find Similar Products
  • Overview
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
WJ321
Integration
GSI
Operating Temperature
-40℃ - 85℃
Resolution
12 Bit
Shape
DIP
Technics
Semiconductor IC
Input Type1
Current Input/Voltage Input
Accuracy
0.1%
Temperature Drift
± 50 Ppm/ºC (± 100 Ppm/ºC,
Input Resistanc
150 Ω (4-20mA/0-20mA/0- ± 20mA Curren
Bandwidth
-3 dB 10 Hz
Power Consumptio
Less Than 3W
Working Temperature
-45~+80 ºC
Working Humidity
10~90% (No Condensation)
Product Features
Convert 4-20mA Signal to Standard Modbus TCP Proto
Transport Package
Wayjunr
Specification
120mm x 70mm x 43mm
Trademark
wayjunr
Origin
Guangdong, China
Production Capacity
9999

Product Description

4-20mA or 0-10V to network Modbus TCP and MQTT, WiFi acquisitionmodule
Product Overview:
The WJ321 product is an IoT and industrial Ethernet acquisition module that enables transparent data exchangebetween sensors and networks. The analog data from sensors can be forwarded to the network.The WJ321 series products include power conditioning, analog data acquisition, and WiFi networkinterfacecommunication. The communication method adopts MODBUS TCP protocol. TCP is a transport layer basedprotocol that is widely used and a reliable connection oriented protocol. Users can directly set module IPaddresses,subnet masks, etc. on the webpage. Can be used for monitoring and controlling the operation of sensor devices. The WJ321 series products are intelligent monitoring and control systems based on microcontrollers, whereusersetmodule IP addresses, subnet masks, and other configuration information are stored in non-volatile memory EEPROM. The WJ321 series products are designed and manufactured according to industrial standards, withstronganti-interference ability and high reliability. The working temperature range is -45 ℃to+80 ℃.
0-75mv Convert to Modbus TCP Network WiFi Collection Module Mes System Sensor Signal
0-75mv Convert to Modbus TCP Network WiFi Collection Module Mes System Sensor Signal
Product model:
WJ321 - U(A)- WiFi

Input voltage or current signal value communication interface
Form of antenna
WiFi
U1:0-5V                   A1:0-1mA
U2:0-10V                 A2:0-10mA
U3:0-75mV             A3:0-20mA
U4:0-2.5V                A4:4-20mA
U5:0-±5V                  A5:0-±1mA
U6:0-±10V                A6:0-±10mA
U7:0-±100mV          A7:0-±20mA
U8: User defined     A8: User defined
W: External antenna
N: Built in antenna
X: Suction cup antenna
Output as WiFi network interface






Company Profile
0-75mv Convert to Modbus TCP Network WiFi Collection Module Mes System Sensor Signal
Shenzhen Weijunrui Technology Co., Ltd
Since: 2011
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc
0-75mv Convert to Modbus TCP Network WiFi Collection Module Mes System Sensor Signal
0-75mv Convert to Modbus TCP Network WiFi Collection Module Mes System Sensor Signal
WJ321 General Parameters:
Function Introduction:

(Typical @+25 ℃, Vs is 24VDC)
Input type: current input/voltage input
Accuracy: 0.1%
Temperature drift: ± 50 ppm/℃ (± 100 ppm/℃, maximum)
Input resistance: 150 Ω (4-20mA/0-20mA/0- ± 20mA current input)
300 Ω (0-10mA/0- ± 10mA current input)
1.5K Ω (0-1mA/0- ± 1mA current input)
Greater than 200K (5V/10V voltage input)
Greater than 1M Ω (input voltage below 2.5V)
Bandwidth: -3 dB 10 Hz
Conversion rate: 16FPS (factory default value, users can modify the conversion rate on the webpage.)
You can set the AD conversion rate to 2SPS, 4SPS, 8SPS, 16SPS, 32SPS, 50SPS, 80SPS, 100SPSbysendingcommands
Common mode rejection (CMR): 120 dB (1k Ω Source Imbalance @ 50/60 Hz)
Normal mode suppression (NMR): 60 dB (1k Ω Source Imbalance @ 50/60 Hz)
Input protection: overvoltage protection, overcurrent protection
Communication: MODBUS TCP communication protocol or TCP socket character protocol or MQTT protocol
Web page: Supports web access module and web page setting module parameters. Interface: WiFi network interface. Communication response time: 100 ms maximum
Working power supply:+8~32VDC wide power supply range, with internal anti reverse and overvoltage protectioncircuits
Power consumption: less than 3W
Working temperature: -45~+80 ℃
Working humidity: 10~90% (no condensation)
Storage temperature: -45~+80 ℃
Storage humidity: 10~95% (no condensation)
Dimensions: 79 mm x 69.5mm x 25mm

The WJ321 remote I/O module can be used to measure one analog signal. 1, Analog signal input
16 bit acquisition accuracy, one analog signal input. All signal input ranges have been calibrated before theproduct leaves the factory. During use, users can also easily program and calibrate themselves. Please refer totheproduct selection for specific current or voltage input range. 2. Communication Protocol
Communication interface: WiFi network interface. Can connect to WiFi within the local area network. Communication protocol: MODBUS TCP protocol is adopted to achieve industrial Ethernet data exchange. It canalso communicate with modules through TCP sockets. Network cache: 2K bytes (for both sending and receiving)
Communication response time: less than 10mS. 3. Anti interference
There is a transient suppression diode inside the module, which can effectively suppress various surge pulsesandprotect the modul