8-Way Ntc Thermistor Temperature Conversion to RS-485/RS232 Data Acquisition Temperature Signal Sensor

Product Details
Customization: Available
Type: Standard DIN35 Rail Installation
Measuring Medium: Temperature
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (21)
  • 8-Way Ntc Thermistor Temperature Conversion to RS-485/RS232 Data Acquisition Temperature Signal Sensor
  • 8-Way Ntc Thermistor Temperature Conversion to RS-485/RS232 Data Acquisition Temperature Signal Sensor
  • 8-Way Ntc Thermistor Temperature Conversion to RS-485/RS232 Data Acquisition Temperature Signal Sensor
  • 8-Way Ntc Thermistor Temperature Conversion to RS-485/RS232 Data Acquisition Temperature Signal Sensor
  • 8-Way Ntc Thermistor Temperature Conversion to RS-485/RS232 Data Acquisition Temperature Signal Sensor
  • 8-Way Ntc Thermistor Temperature Conversion to RS-485/RS232 Data Acquisition Temperature Signal Sensor
Find Similar Products
  • Overview
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
WJ226
Display Type
LCD
Site Display
Site Display
Accuracy
0.1
IP Rating
IP20
Certification
CE
Customized
Customized
Input Type
Ntc Thermistor Input
Product Features
Eight Channel Ntc Temperature Acquisition, Isolate
Typical Applications
Ntc Temperature Signal Measurement
Typical Applications1
RS-485 Remote I/O, Data Acquisition
Typical Applications2
Intelligent Building Control, Security Engineering
Wide Power Supply Rang
8~32VDC
Quantity
99999
Transport Package
Wayjunr
Specification
120mm x 70mm x 43mm
Trademark
wayjunr
Origin
Guangdong, China
Production Capacity
9999

Product Description

 8-way NTC thermistor temperature conversion to RS-485/232, data acquisition
 module WJ226
 Product features:
 Eight channel NTC temperature acquisition, isolated conversion to RS-485/232 output
 Can be quickly customized and linearized according to the NTC scale table
 Supports various NTC sensors such as 5K/10K/20K/100K
 Using a 12 bitAD converter, the measurement accuracy is better than 0.1%
 Isolation withstand voltage between signal input/output 1000VDC
 Wide power supply range: 8~32VDC
 High reliability, easy programming, and easy application
 Standard DIN35 rail installation, convenient for centralized wiring
 Users can program module addresses, baud rates, etc
 Supports Modbus RTU communication protocol and automatic recognition protocol
 Industrial flame retardant shell, RS485 port surge protection
 Typical applications:
 NTC temperature signal measurement
 RS-485 remote I/O, data acquisition
 Intelligent building control, security engineering and other application systems
 RS-232/485 bus industrial automation control system
 Industrial site signal isolation and long-distance transmission
 Equipment operation monitoring
 Measurement of sensor signals
 Acquisition and recording of industrial field data
 Development of medical and industrial control products
 Thermistor signal acquisition
8-Way Ntc Thermistor Temperature Conversion to RS-485/RS232 Data Acquisition Temperature Signal Sensor
8-Way Ntc Thermistor Temperature Conversion to RS-485/RS232 Data Acquisition Temperature Signal Sensor
Product selection:
WJ226- Z- T- 

Input type: NTC
NTC1K
 NTC5K
 NTC10K
 NTC20K
 NTC50K
 NTC100K
Other NTC
Temperature
 range: T
 T1:-20-100℃
 T2: 0-100℃
 T3: 0-150℃
 T4: 0-200℃
 T5: 0-400℃
 Tu: User defined
communication interface
 232: Output as RS-232 interface
 485: Output as RS-485 interface
Selection Example 1: Model: WJ226-NTC10K-T1-485 indicates Input: NTC10K, Temperature Range:-20~100 ℃,
 Output: RS-485
Selection example 2: Model: WJ226-NTC20K-T4-485 indicates input: NTC20K, temperature range: 0~200 ℃, output
 is RS-485
Selection example 3: Model: WJ226-NTC3K-Tu-232 indicates input: NTC3K, temperature range: 0~50 ℃, output is
 RS-232






Company Profile
8-Way Ntc Thermistor Temperature Conversion to RS-485/RS232 Data Acquisition Temperature Signal Sensor
Shenzhen Weijunrui Technology Co., Ltd
Since: 2011
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc
8-Way Ntc Thermistor Temperature Conversion to RS-485/RS232 Data Acquisition Temperature Signal Sensor
8-Way Ntc Thermistor Temperature Conversion to RS-485/RS232 Data Acquisition Temperature Signal Sensor
Global Showrooms
Factory Capabilities
 WJ226 General Parameters:
 (Typical @+25 ℃, Vs is 24VDC)
 Input type: NTC thermistor input
 Accuracy: 0.1%
 Temperature drift: ± 50 ppm/℃ (± 100 ppm/℃, maximum)
 Bandwidth:-3 dB 10 Hz
 Conversion rate: 5 Sps (factory default value, users can modify the conversion rate by issuing commands.)
 You can set the AD conversion rate to 2.5 SPS, 5 SPS, 10 SPS, and 20 SPS by sending commands. (Channel
 conversion rate=AD conversion rate/number of open channels)
 Note: Please recalibrate the module after modifying the conversion rate, otherwise the measured data may have
 deviations. You can also specify the conversion rate when placing an order, and we will
 recalibrate the product according to the conversion rate you require when it leaves the factory.
 Common moderejection (CMR): 120 dB (1k Ω Source Imbalance @ 50/60 Hz)
 Normal mode suppression (NMR): 60 dB (1k Ω Source Imbalance @ 50/60 Hz)
 Input protection: overvoltage protection, overcurrent protection
 Communication: RS-485 or RS-232 standard character protocol and MODBUS RTU communication protocol
 Baud rates (2400, 4800, 9600, 19200, 38400, 57600, 115200bps) can be selected by software
 The address (0-255) can be selected by software
 Communication response time: 100 ms maximum
 Working power supply:+8~32VDC wide power supply range, with internal anti reverse and overvoltage protection
 circuits
 Power consumption: less than 1W
 Working temperature:-40~+85 ℃
 Working humidity: 10~90% (no condensation)
 Storage temperature:-40~+85 ℃
 Storage humidity: 10~95% (no condensation)
 Isolation withstand voltage: 1KVDC between input/output, 1 minute, leakage current 1mA
 The RS-232/RS-485 output and power supply are grounded together.
 Surge resistant voltage: 3KVAC, 1.2/50us (peak)
 Dimensions: 120mm x 70mm x 43mm
 Function Introduction:
 The WJ226 signal isolation acquisition module can be used to measure eight NTC thermistor signals.
 1,Analog signal input
 12 bit acquisition accuracy, 8-channel NTC thermistor signal input. All signal input ranges have been calibrated
 before the product leaves the factory. Users do not need to calibrate.
 2,Communication Protocol
 Communication interface: 1 standard RS-485 communication interface or 1 standard RS-232 communication
 interface, please specify when ordering and selecting.
 Communication Protocol: Supports two protocols, the character protocol defined by the command set and the
 MODBUSRTUcommunication protocol. The module automatically recognizes communication
 protocols and can achieve network communication with various brands of PLCs, RTUs, or computer
 monitoring systems.
 Data format: 10 digits. 1 start bit, 8 data bits, and 1 stop bit.
 The communication address (0-255) and baud rate (2400, 4800, 9600, 19200, 38400, 57600, 115200bps) can be set;
 The communication network can reach a maximum distance of 1200 meters and is connected through
 twisted pair shielded cables.
 High anti-interference design of communication interface, ± 15KV ESD protection, communication response time
 less than 100mS.
 3,anti-interference
 Checksums can be set as needed. There is a transient suppression diode inside the module, which can effectively
 suppress various surge pulses, protect the module, and the internal digital filter can also effectively suppress power
 frequency interference from the power grid.
FAQ
Q: How to contact you?
A: Please contact us via email or online customer service

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier