4-Channel Differential Encoder Pulse Counter Speed Measurement Modbusrtu

Product Details
Customization: Available
Type: Software Decoder
Housing Material: Paint Tin
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (21)
  • 4-Channel Differential Encoder Pulse Counter Speed Measurement Modbusrtu
  • 4-Channel Differential Encoder Pulse Counter Speed Measurement Modbusrtu
  • 4-Channel Differential Encoder Pulse Counter Speed Measurement Modbusrtu
  • 4-Channel Differential Encoder Pulse Counter Speed Measurement Modbusrtu
  • 4-Channel Differential Encoder Pulse Counter Speed Measurement Modbusrtu
  • 4-Channel Differential Encoder Pulse Counter Speed Measurement Modbusrtu
Find Similar Products
  • Overview
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
WJ67
Means of Communication
One-Way Communication
Operating System
Contact Brush Type
Package
DIP
Interface Rate
38400bps
Application
Encoder Pulse Signal Measurement
Modulation Method
QPSK
Installation Form
Standard DIN35 Rail Installation
Brand
Wayjunr
Typical Applications
Flow Meter Pulse Counting or Flow Measurement
Product Features
Encoders Decode and Convert to Standard Modbus RTU
Typical Applications1
Logistics Package Quantity Counting
Wide Power Supply Range
8~32VDC
Product Features1
Users Can Program Module Addresses, Baud Rates, Et
Input Type
5V Differential Signal Input
Input Type1
Differential Signal Range ± 200mv~±
Transport Package
Boxed
Specification
120mm x 70mm x 43mm
Trademark
wayjunr
Origin
Guangdong, China
Production Capacity
99999

Product Description

 4-channel differential encoder pulse counter, speed measurement, Modbus RTU
 module WJ67
 Product features:
 Encoders decode and convert to standard Modbus RTU protocol
 Encoder 5V differential signal input directly
 Can be used as an encoder counter or speed measurement
 Supports simultaneous counting of 4 encoders and can recognize forward and reverse rotation
 It can also be set as an 8-channel independent DI high-speed counter
 The encoder count value supports automatic power-off saving
 3000V isolation between DI input and power supply
 Reset and set count values through RS-485/232 interface
 Wide power supply range: 8~32VDC
 High reliability, easy programming, and easy application
 Standard DIN35 rail installation, convenient for centralized wiring
 Users can program module addresses, baud rates, etc
 Dimensions: 120mm x 70mm x 43mm
 Typical applications:
 Encoder pulse signal measurement
 Flow meter pulse counting or flow measurement
Counting of products on the production line
Logistics package quantity counting
 Measurement of proximity switch pulse signal
 The encoder signal is transmitted remotely to the industrial computer
 Intelligent factory and industrial Internet of Things
 Replace PLC to directly transmit data to the control center
4-Channel Differential Encoder Pulse Counter Speed Measurement Modbusrtu
4-Channel Differential Encoder Pulse Counter Speed Measurement Modbusrtu
Product selection
WJ67-



Communication interface

485: Output as RS-485 interface


232: Output as RS-232 interface

Selection Example 1: Model: WJ67-232 indicates an output of RS-232 interface
Selection Example 2: Model: WJ67-485 indicates output as RS-485 interface

Company Profile
4-Channel Differential Encoder Pulse Counter Speed Measurement Modbusrtu
Shenzhen Weijunrui Technology Co., Ltd
Since: 2011
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc
4-Channel Differential Encoder Pulse Counter Speed Measurement Modbusrtu
4-Channel Differential Encoder Pulse Counter Speed Measurement Modbusrtu
Global Showrooms
Factory Capabilities
WJ67 General Parameters:
 (Typical @+25 ℃, Vs is 24VDC)
 Input type: 5V differential signal input. Differential signal range ± 200mV~± 7V.
 The frequency range is 0-20KHz (all channels input simultaneously), and a single channel can support 50KHz input.
 Encoder count range-2147483647 ~+2147483647 , automatically saved upon power failure
 DI counter range 0~ 4294967295 , power off and reset to zero
 Communication:RS-485orRS-232standardcharacterprotocolandMODBUSRTUcommunicationprotocol
 Baudrates(2400,4800,9600,19200,38400,57600,115200bps)canbeselectedbysoftware
 Theaddress(0-255)canbeselectedbysoftware
 Communicationresponsetime:100msmaximum
 Workingpower supply:+8~32VDCwidepower supply range,with internal anti reverse andovervoltage protection
 circuits
 Powerconsumption:lessthan1W
 Workingtemperature:-45~+80℃
 Workinghumidity:10~90%(nocondensation)
 Storagetemperature:-45~+80℃
 Storagehumidity:10~95%(nocondensation)
 Isolationandvoltage resistance: 3000VisolationbetweenDI input andpower supply, communication interfaceand
 powersupplyaregroundedtogether.
 Dimensions:120mmx70mmx43mm
 Function Introduction:
 The WJ67 remote I/O module can be used to measure four encoder signals or set as an eight channel independent
 counter.
 1,Signal input
 4-channel encoder 5V differential signal input or 8-channel 5V differential signal independent counter.
 2,Communication Protocol
 Communication interface: 1 standard RS-485 communication interface or 1 standard RS-232 communication
 interface, please specify when ordering and selecting.
 Communication Protocol: Supports two protocols, the character protocol defined by the command set and the
 MODBUSRTUcommunication protocol. The module automatically recognizes communication
 protocols and can achieve network communication with various brands of PLCs, RTUs, or computer
 monitoring systems.
 Data format: 10 digits. 1 start bit, 8 data bits, and 1 stop bit. No verification.
 The communication address (0-255) and baud rate (2400, 4800, 9600, 19200, 38400, 57600, 115200bps) can be set;
 The communication network can reach a maximum distance of 1200 meters and is connected through
 twisted pair shielded cables.
 High anti-interference design of communication interface, ± 15KV ESD protection, communication response time
 less than 100mS.
 3,anti-interference
 Checksums can be set as needed. There is a transient suppression diode inside the module, which can effectively
 suppress various surge pulses, protect the module, and the internal digital filter can also effectively suppress power
 frequency interference from the power grid
Certifications
FAQ
Q: How to contact you?
A: Please contact us via email or online customer service

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier