Convert Differential Encoder to Standard Modbus RTU Protocol Speed Measurement Independent Differential Counter

Still deciding? Get samples of $ !
Order Sample
Product Details
Customization: Available
Type: Rotary Encoder
Working Principle: Absolute
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (21)
  • Convert Differential Encoder to Standard Modbus RTU Protocol Speed Measurement Independent Differential Counter
  • Convert Differential Encoder to Standard Modbus RTU Protocol Speed Measurement Independent Differential Counter
  • Convert Differential Encoder to Standard Modbus RTU Protocol Speed Measurement Independent Differential Counter
  • Convert Differential Encoder to Standard Modbus RTU Protocol Speed Measurement Independent Differential Counter
  • Convert Differential Encoder to Standard Modbus RTU Protocol Speed Measurement Independent Differential Counter
  • Convert Differential Encoder to Standard Modbus RTU Protocol Speed Measurement Independent Differential Counter
Find Similar Products
  • Overview
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
WJ157
Readout Mode
Contact
Operating System
Contact Brush Type
Signal Output
Long Drive Output
Axle Sleeve Type
Large Diameter Type
Package
Wayjunr
Installation Form
Standard DIN35 Rail Installation, Convenient for C
Brand
Wayjunr
Axonia
Servo Installation Type
Product Features
Convert Differential Encoder to Standard Modbus Rt
Product Features1
Encoder 5V Differential Signal Input Directly
Product Features2
Can Be Used as a Differential Encoder Counter or S
Product Features3
The Encoder Count Value Supports Automatic Power-O
Product Features4
The Module Can Output a 5V Power Supply to Power T
Product Features5
High Reliability, Easy Programming, and Easy Appli
Product Features6
Users Can Program Module Addresses, Baud Rates, Et
Typical Applications
Encoder Pulse Signal Measurement
Typical Applications1
Flow Meter Pulse Counting or Flow Measurement
Transport Package
Wayjunr
Specification
106 mm x 59mm x 37mm
Trademark
WAYJUNR
Origin
China
Production Capacity
99999

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 20.00cm
Package Gross Weight
0.200kg

Product Description

Differential encoder pulse counter or speed measurement, Modbus RTU module
WJ157
Product features:
Convert differential encoder to standard Modbus RTU protocol
Encoder 5V differential signal input directly
Can be used as a differential encoder counter or speed measurement
Differential 5V signal input directly, encoder counting, can recognize forward and reverse rotation
 It can also be set as a 2-channel independent DI high-speed counter
The encoder count value supports automatic power-off saving
The module can output a 5V power supply to power the encoder
Reset and set count values through RS-485 interface
Wide power supply range: 8~32VDC
High reliability, easy programming, and easy application
Standard DIN35 rail installation, convenient for centralized wiring
Users can program module addresses, baud rates, etc
Typical applications:
Encoder pulse signal measurement
WJ157
 Flow meter pulse counting or flow measurement
Production line product counting
Counting the number of logistics packages
The encoder signal is transmitted remotely to the industrial computer
Intelligent factory and industrial Internet of Things
Replace PLC to directly transmit data to the control center
Convert Differential Encoder to Standard Modbus RTU Protocol Speed Measurement Independent Differential Counter
Convert Differential Encoder to Standard Modbus RTU Protocol Speed Measurement Independent Differential Counter
Product selection:
WJ157 -
Communication interface
485: Output as RS-485 interface













Company Profile
Convert Differential Encoder to Standard Modbus RTU Protocol Speed Measurement Independent Differential Counter
Shenzhen Weijunrui Technology Co., Ltd
Since: 2011
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc
Convert Differential Encoder to Standard Modbus RTU Protocol Speed Measurement Independent Differential Counter
Convert Differential Encoder to Standard Modbus RTU Protocol Speed Measurement Independent Differential Counter
Product Overview:
Function Introduction:

The WJ157 product realizes signal acquisition between sensors and hosts, used to decode encoder signals.
The
WJ157 series products can be applied in RS-485 bus industrial automation control systems, automated machine tools,
industrial robots, three coordinate positioning systems, displacement measurement, stroke measurement, angle
measurement, speed measurement, flow measurement, product counting, and more.
The product includes signal acquisition, pulse signal capture, signal conversion, and RS-485 serial communication.
Each serial port can connect up to 255 WJ157 series modules, and the communication method adopts ASCII code
communication protocol or MODBUS RTU communication protocol. The baud rate can be set by code and can be hung
on the same RS-485 bus as control modules from other manufacturers, making it easy for computer programming.The WJ157 series products are intelligent monitoring and control systems based on microcontrollers. All user set
configuration information such as address, baud rate, data format, parity status, etc. are stored in non-volatile memory
EEPROM.
The WJ157 series products are designed and manufactured according to industrial standards, with no isolation
between signal inputs/outputs, strong anti-interference ability, and high reliability.
The working temperature range is
-45 ℃ to+85 ℃.

The WJ157 remote I/O module can be used to measure 1 differential encoder signal or set as 2 independent differential
counters.
1, Signal input
One 5V differential encoder signal input or two independent 5V differential counters.
2, Communication Protocol
Communication interface: 1 standard RS-485 communication interface.
Communication Protocol: Supports two protocols, the character protocol defined by the command set and the
MODBUS RTU communication protocol.
The module automatically recognizes communication
protocols and can achieve network communication with various brands of PLCs, RTUs, or computer
monitoring systems.
Data format: 10 digits.
1 start bit, 8 data bits, and 1 stop bit.
No verification.
The communication address (0-255) and baud rate (2400, 4800, 9600, 19200, 38400, 57600, 115200bps) can be set;
The communication network can reach a maximum distance of 1200 meters and is connected through
twisted pair shielded cables.
High anti-interference design of communication interface, ± 15KV ESD protection, communication response time
less than 100mS.
3, anti-interference
Parity check can be set as needed.
There is a transient suppression diode inside the module, which can effectively
suppress various surge pulses, protect the module, and the internal digital filter can also effectively suppress power
frequency interference from the power grid.
FAQ
Q: How to contact you?
A: Please contact us via email or online customer service

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now
People who viewed this also viewed