4-20mA or 0-10V to Network RJ45 Mqtt Data Collection Module Mes System Remote I/O Module

Product Details
Customization: Available
Product Features: Convert 4-20mA Signal to Standard Modbus TCP Proto
Product Features1: Supports Communication Protocols Such as TCP Serve
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (21)
  • 4-20mA or 0-10V to Network RJ45 Mqtt Data Collection Module Mes System Remote I/O Module
  • 4-20mA or 0-10V to Network RJ45 Mqtt Data Collection Module Mes System Remote I/O Module
  • 4-20mA or 0-10V to Network RJ45 Mqtt Data Collection Module Mes System Remote I/O Module
  • 4-20mA or 0-10V to Network RJ45 Mqtt Data Collection Module Mes System Remote I/O Module
  • 4-20mA or 0-10V to Network RJ45 Mqtt Data Collection Module Mes System Remote I/O Module
  • 4-20mA or 0-10V to Network RJ45 Mqtt Data Collection Module Mes System Remote I/O Module
Find Similar Products
  • Overview
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
WJ181
Product Features2
Built in Web Page Function, Data Can Be Queried T
Product Features3
High Reliability, Easy Programming, and Easy Appli
Product Features4
Low Cost, Small Size, Modular Design
Product Features5
Signal Measurement, Monitoring, and Mqtt Reporting
Product Features6
Modbus Tcpnetwork, Data Acquisition
Product Features7
Industrial Automation Control System
Product Features8
Equipment Operation Monitoring, Mes System
Transport Package
Wayjunr
Specification
120mm x 70mm x 43mm
Trademark
wayjunr
Origin
Guangdong, China
Production Capacity
9999

Product Description

4-20mAor0-10V to network ModbusTCPand MQTTdata acquisition module
 WJ181
Product features:
 Convert 4-20mA signal to standard Modbus TCP protocol
 Supports communication protocols such as TCP Server, UDP, MQTT, etc
 Built in web page function, data can be queried through web pages
 Wide power supply range: 8~32VDC
 High reliability, easy programming, and easy application
 Standard DIN35 rail installation, convenient for centralized wiring
 Users can set module IP addresses and other parameters on the webpage
 Low cost, small size, modular design
 Dimensions: 106 mm x 59mm x 37mm
 Typical applications:
 Signal measurement, monitoring, and MQTT reporting
 Modbus TCPnetwork, data acquisition
 Intelligent building control, security engineering and other application systems
 industrial automation control system
 Industrial site signal isolation and long-distance transmission
 Equipment operation monitoring, MES system
 Measurement of sensor signals
 Acquisition and recording of industrial field data
 Development of medical and industrial control products
 4-20mAor 0-5V signal acquisition
4-20mA or 0-10V to Network RJ45 Mqtt Data Collection Module Mes System Remote I/O Module
4-20mA or 0-10V to Network RJ45 Mqtt Data Collection Module Mes System Remote I/O Module
Product model:
WJ181- U(A)-RJ45

Input voltage or current signal value
Communication interface

U1:0-5V                   A1:0-1mA
U2:0-10V                 A2:0-10mA
U3:0-75mV             A3:0-20mA
U4:0-2.5V                A4:4-20mA
U5:0-±5V                 A5:0-±1mA
U6:0-±10V               A6:0-±10mA
U7:0-±100mV         A7:0-±20mA
U8: User defined       A8: User defined
RJ45: Output as RJ-45 network interface

Selection Example 1: Model: WJ181-A4-RJ45 represents one 4-20mA signal input and an RJ-45 network interface
 output
 Selection Example 2: Model: WJ181-U1-RJ45 represents one 0-5V signal input, and the output is an RJ-45 network
 interface





Company Profile
4-20mA or 0-10V to Network RJ45 Mqtt Data Collection Module Mes System Remote I/O Module
Shenzhen Weijunrui Technology Co., Ltd
Since: 2011
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc
4-20mA or 0-10V to Network RJ45 Mqtt Data Collection Module Mes System Remote I/O Module
4-20mA or 0-10V to Network RJ45 Mqtt Data Collection Module Mes System Remote I/O Module
Product Overview:
 Function Introduction:
The WJ181 product is an IoT and industrial Ethernet acquisition module that enables transparent data exchange
 between sensors and networks. The analog data from sensors can be forwarded to the network. The WJ181 series products include power conditioning, analog acquisition, and RJ-45 network interface
 communication.
 The communication method adopts MODBUS TCP protocol. TCP is a transport layer based
 protocol that is widely used and a reliable connection oriented protocol. Users can directly set module IP addresses,
 subnet masks, etc. on the webpage. Can be used for monitoring and controlling the operation of sensor devices.
 The WJ181 series products are intelligent monitoring and control systems based on microcontrollers, where user set  module IP addresses, subnet masks, and other configuration information are stored in non-volatile memory EEPROM.
 The WJ181 series products are designed and manufactured according to industrial standards, with strong
 anti-interference ability and high reliability. The working temperature range is-45 ℃ to+80 ℃.

 The WJ181 remote I/O module can be used to measure one analog signal.
 1. Analog signal input
 12 bit acquisition accuracy, one analog signal input. All signal input ranges have been calibrated before the product
 leaves the factory. During use, users can also easily program and calibrate themselves. Please refer to the product
 selection for specific current or voltage input range.
 2. Communication Protocol
 Communication interface: RJ-45 network interface. The two indicator lights at the network port position, the Link
 light (green light) stays on and the Data light (yellow light) stays on after the network cable is plugged in.
 Communication protocol: MODBUS TCP protocol is adopted to achieve industrial Ethernet data exchange. It can
 also communicate with modules through TCP sockets.
 Network cache: 2K bytes (for both sending and receiving)
 Communication response time: less than 10mS.
 3. Anti interference
 There is a transient suppression diode inside the module, which can effectively suppress various surge pulses and
 protect the module.
FAQ
Q: How to contact you?
A: Please contact us via email or online customer service

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier