Flow Meter Pulse Counting or Flow Measurement Speed Measurement, Modbus RTU Module

Still deciding? Get samples of $ !
Order Sample
Product Details
Customization: Available
Conductive Type: Bipolar Integrated Circuit
Integration: GSI
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 4 Self-brands, check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (21)
  • Flow Meter Pulse Counting or Flow Measurement Speed Measurement, Modbus RTU Module
  • Flow Meter Pulse Counting or Flow Measurement Speed Measurement, Modbus RTU Module
  • Flow Meter Pulse Counting or Flow Measurement Speed Measurement, Modbus RTU Module
  • Flow Meter Pulse Counting or Flow Measurement Speed Measurement, Modbus RTU Module
  • Flow Meter Pulse Counting or Flow Measurement Speed Measurement, Modbus RTU Module
  • Flow Meter Pulse Counting or Flow Measurement Speed Measurement, Modbus RTU Module
Find Similar Products
  • Overview
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
WJ67
Output Type
Current Output
Resolution
10 Bit
Shape
DIP
Technics
Semiconductor IC
Typical Applications
Encoder Pulse Signal Measurement
Typical Applications1
Flow Meter Pulse Counting or Flow Measurement
Typical Applications2
Counting of Products on The Production Line
Typical Applications3
Logistics Package Quantity Counting
Typical Applications4
Intelligent Factory and Industrial Internet of Thi
Typical Applications5
Replace PLC to Directly Transmit Data to The Contr
Product Features
Encoders Decode and Convert to Standard Modbus RTU
Product Features:1
Encoder 5V Differential Signal Input Directly
Transport Package
Wayjunr
Specification
120mm x 70mm x 43mm
Trademark
wayjunr
Origin
Guangdong, China
Production Capacity
9999

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 20.00cm
Package Gross Weight
0.200kg

Product Description

4-channel differential encoder pulse counter, speed measurement, Modbus RTU
module WJ67
Product Overview:
The WJ67 product realizes signal acquisition between sensors and hosts, used to decode encoder signals.
The
WJ67 series products can be applied in industrial automation control systems based on the RS-232/485 bus, automated
machine tools, industrial robots, coordinate positioning systems, displacement measurement, stroke measurement, angle
measurement, speed measurement, flow measurement, product counting, and more.
The product includes signal isolation, pulse signal capture, signal conversion, and RS-485 serial communication.
Each serial port can connect up to 255 WJ67 series modules, and the communication method adopts ASCII code
communication protocol or MODBUS RTU communication protocol. The baud rate can be set by code and can be hung
on the same RS-485 bus as control modules from other manufacturers, making it easy for computer programming.
The WJ67 series products are intelligent monitoring and control systems based on microcontrollers. All user set
configuration information such as address, baud rate, data format, checksum status, etc. are stored in non-volatile
memory EEPROM.
The WJ67 series products are designed and manufactured according to industrial standards, with no isolation
between signal inputs/outputs, strong anti-interference ability, and high reliability.
The working temperature range is
-45 ℃ to+85 ℃.
Flow Meter Pulse Counting or Flow Measurement Speed Measurement, Modbus RTU Module
Flow Meter Pulse Counting or Flow Measurement Speed Measurement, Modbus RTU Module
Product selection:
WJ67 -
Communication interface


485: Output as RS-485 interface
232: Output as RS-232 interface



Selection Example 1: Model: WJ67-232 indicates an output of RS-232 interface
Selection Example 2: Model: WJ67-485 indicates output as RS-485 interface







Company Profile
Flow Meter Pulse Counting or Flow Measurement Speed Measurement, Modbus RTU Module
Shenzhen Weijunrui Technology Co., Ltd
Since: 2011
Specialty: The company's main products include analog acquisition modules, signal isolators/conversion modules, and signal transmitters
Capacity: Produce 10000 per month
Advanced Features:
Switching to TCP/network/remote IO module, Modbus RTU to TCP, RS232/485 to Ethernet, analog signal (current/voltage/thermistor/frequency/displacement/speed/pulse) isolation transmitter, mV differential signal amplifier, isolation amplifier, micro power DC-DC module power supply, etc
Flow Meter Pulse Counting or Flow Measurement Speed Measurement, Modbus RTU Module
Flow Meter Pulse Counting or Flow Measurement Speed Measurement, Modbus RTU Module
Function Introduction:
WJ67 General Parameters:

The WJ67 remote I/O module can be used to measure four encoder signals or set as an eight channel independent
counter.
1, Signal input
4-channel encoder 5V differential signal input or 8-channel 5V differential signal independent counter.
2, Communication Protocol
Communication interface: 1 standard RS-485 communication interface or 1 standard RS-232 communication
interface, please specify when ordering and selecting.
Communication Protocol: Supports two protocols, the character protocol defined by the command set and the
MODBUS RTU communication protocol.
The module automatically recognizes communication
protocols and can achieve network communication with various brands of PLCs, RTUs, or computer
monitoring systems.
Data format: 10 digits.
1 start bit, 8 data bits, and 1 stop bit.
No verification.
The communication address (0-255) and baud rate (2400, 4800, 9600, 19200, 38400, 57600, 115200bps) can be set;
The communication network can reach a maximum distance of 1200 meters and is connected through
twisted pair shielded cables.
High anti-interference design of communication interface, ± 15KV ESD protection, communication response time
less than 100mS.
3, anti-interference
Checksums can be set as needed.
There is a transient suppression diode inside the module, which can effectively
suppress various surge pulses, protect the module, and the internal digital filter can also effectively suppress power
frequency interference from the power grid.

(Typical @+25 ℃, Vs is 24VDC)
Input type: 5V differential signal input.
Differential signal range ± 200mV~± 7V.
The frequency range is 0-20KHz (all channels input simultaneously), and a single channel can support 50KHz input.
Encoder count range
-2147483647 ~+2147483647 , automatically saved upon power failure
DI counter range 0~ 4294967295 , power off and reset to zero
Communication: RS-485 or RS-232 standard character protocol and MODBUS RTU communication protocol
Baud rates (2400, 4800, 9600, 19200, 38400, 57600, 115200bps) can be selected by software
The address (0-255) can be selected by software
Communication response time: 100 ms maximum
Working power supply:+8~32VDC wide power supply range, with internal anti reverse and overvoltage protection
circuits
Power consumption: less than 1W
Working temperature: -45~+80 ℃
Working humidity: 10~90% (no condensation)
Storage temperature: -45~+80 ℃
Storage humidity: 10~95% (no condensation)
Isolation and voltage resistance: 3000V isolation between DI input and power supply, communication interface and
power supply are grounded together.
Dimensions: 120mm x 70mm x 43mm